How to Compare Waterproof Vent Plug Airflow Ratings

How to Compare Waterproof Vent Plug Airflow Ratings

2026-11-19

Airflow is an important factor when selecting a waterproof vent plug for an electrical enclosure or outdoor electronic device. However, a higher airflow rating does not always mean a better fit.

To compare products accurately, engineers need to consider the test pressure differential, enclosure volume, temperature changes, and waterproof requirements.

1. Compare Airflow at the Same Pressure Differential

Waterproof vent plug airflow is typically measured in mL/min or L/min at a specified pressure differential (ΔP).

Consider two hypothetical products:

Parameter

Vent A

Vent B

Airflow

10 mL/min

15 mL/min

Pressure differential

1 kPa

3 kPa

Vent B has a higher airflow rating, but it was tested at a higher pressure differential. These figures cannot be directly compared.

Before comparing specifications, confirm the measurement units, test pressure, and whether airflow was measured through the membrane alone or the complete valve assembly.

For reference, 1 L/min = 1,000 mL/min, and 1 kPa = 10 mbar.

2. Compare HOAN Waterproof Vent Plug Specifications

Xi'an Hoan Microwave Co., Ltd. offers waterproof breathable valves with different airflow ratings and mounting dimensions.

The following values are taken from HOAN's published product specifications.

Model

Airflow (mL/min)

Test ΔP

Thread

HA-5B-1

7

1KPa

M5 × 0.8

HA-5B-4

11

1KPa

M5 × 0.8

HA-4C

12

1KPa

M4 × 0.7

Source: HOAN published specifications. Values are nominal ratings, not new comparative test results.

All three models have published airflow ratings at 1 kPa, allowing an initial comparison.

The HA-4C has the highest listed airflow, while the HA-5B-1 has the lowest. However, mounting dimensions and actual pressure equalization requirements must also be considered.

How to Compare Waterproof Vent Plug Airflow Ratings 

3. Membrane Airflow vs. Complete Valve Airflow

Airflow measured through a membrane sample may differ from that of a complete waterproof vent plug.

The assembled valve includes a housing, supporting structure, and internal air passages, which may restrict airflow.

When comparing products from different suppliers, confirm whether the published rating represents the membrane alone or the complete valve assembly.

For enclosure applications, complete-assembly airflow data is generally more useful.

4. How Enclosure Volume and Temperature Affect Airflow

Enclosure volume and temperature variation (ΔT) directly influence pressure equalization requirements.

Consider two sealed enclosures with internal volumes of 2 L and 20 L.

If both experience the same temperature change over the same period, the larger enclosure generally requires more air exchange to maintain a similar pressure balance.

For example, assuming ideal-gas behavior, a temperature increase from 20°C to 40°C would require approximately:

Enclosure Volume

Estimated Air Exchange

2L

136ml

20L

1365ml

These are simplified theoretical estimates assuming approximately constant internal pressure, not actual HOAN vent test results.

During cooling, insufficient airflow may cause negative pressure inside the enclosure. This pressure difference can encourage outside air to enter through weak or damaged seals, potentially introducing moisture and increasing condensation risk.

Therefore, vent selection should consider enclosure volume, temperature change rate, allowable pressure difference, and sealing conditions.

5. Check Waterproof Protection and Installation

Higher airflow does not necessarily mean better waterproof performance.

HOAN's published specifications list water-blocking pressure of -120 mbar, an applicable temperature range of -50°C to +150°C, and IP67 or IP68 protection options.

The exact water-blocking test method and applicable IP rating should be confirmed for each product configuration.

Mounting requirements are equally important. Engineers should verify thread size, installation space, and sealing arrangements before selecting a valve.

How to Compare Waterproof Vent Plug Airflow Ratings 

6. What Should You Request Before Purchasing?

Before choosing a waterproof breathable valve, request the following information:

· Airflow rating and corresponding pressure differential

· Complete-valve airflow test data

· Water-blocking pressure and applicable IP test conditions

· Mounting dimensions and sealing requirements

· Operating temperature range

For applications involving frequent temperature changes, an airflow-versus-pressure differential curve can help evaluate the required pressure equalization performance.

Conclusion

Waterproof vent plug airflow ratings should be compared under equivalent test conditions rather than by numerical value alone.

Pressure differential, enclosure volume, temperature changes, waterproof protection, and mounting dimensions all affect the final selection.

Need help selecting a waterproof breathable valve?

Contact Xi'an Hoan Microwave Co., Ltd. with your enclosure volume, operating temperature range, waterproof requirements, and mounting dimensions.

Website: https://www.hoanisolator.com/